(1) The oil level in the oil-gas separator. Remember to check during operation, because all the oil returns to the original position during shutdown. If the oil level is too low, add lubricating oil. When refueling, stop the machine first and loosen the refueling plug for refueling after pressure relief.
(2) The integrity of the hose. Whether there is leakage.
(3) All electrical connectors shall be stable and in good condition.
(4) Water gas separator, ball valve, screw unit, automatic discharge of condensate.
(5) The exhaust temperature shall be within the specified value of 75 ~ 95 ℃.
(6) Check and record voltage, current, exhaust pressure, exhaust temperature, oil level, etc. regularly during operation.
(7) Whether the pressure switch works normally, whether the compressor is unloaded when the working pressure is at the upper limit and loaded when the working pressure is at the lower limit.
(8) Close the door of the acoustic enclosure after inspection.